2318 Delancey Place, Philadelphia
technical data · neighborhood and transit
Quick answers
- Does 2318 Delancey Place have open permits or code violations?
- Philadelphia Department of Licenses and Inspections lists 43 permits, 10 not closed, and 35 violations, 1 open.
- What is the 2026 conforming loan limit in Philadelphia County?
- $832,750 for a single-unit home, per FHFA. Larger loans are jumbo loans.
- Is radon a problem here?
- EPA radon zone 2, moderate potential.
- What natural disasters is 2318 Delancey Place at risk for?
- FEMA's National Risk Index rates the area relatively high overall, with elevated inland flooding and heat wave risk.
Permits and code violations
10 permits not closed out. Unfinished permits pass to the next owner. 1 open violation.
- Mechanical / fuel gas permit Aug 2025Issued
Ez permit ductwork & warm-air appliances- for the installation if new ductwork, registers/grilles/diffusers, and warm-air appliances as per attached standards. deviations from these standards require submission of construction and site plans. 3 condensing units on the roof top as per engineer plans. **philadelphia historic approval required.*** requested plans showing condensers' location. plans submitted for previous permit application (#rp-2024-002549, plans stamped by phc staff member daniel shachar-krasnoff), but still applicable to this permit application, were uploaded to eclipse and sent to staff (joshua schroeder) by email on 8/13/2025. plans show condensers on roof will be inconspicuous with regard to public visibility. applicants also affirmed by email that all other hvac conduits / equipment will be installed in the buildings interior. approval only covers three condensers on roof and specified interior hvac work(as per phc conditions). install 2 (36k btu) unico high velocity systems, 1 (30k btu) unico high velocity system and 1 (150k btu) boiler; 63 supply outlets; 4 return vents; connected to 3 outdoor condensers on the roof; 1600 total cfm amongst all 3 air handlers combined (high velocity 600 cfm+600 cfm+400cfm)
- Residential building permit Jun 2025Issued
For alterations/repairs to an existing rear garage of a single-family dwelling as per application/plans and phc approval.
- Plumbing permit May 2025Issued
New waste and water piping for 6 water closets, 6 lavatories, 4 showers, 1 tub, 3 wet bars, 1 kitchen sink, 1 laundry box and 1 laundry tub, 1 sump pump installation of 2 water heaters installation of fixtures with piping 26 fixtures
- Site / utility permit Mar 2025Issued
For excavation work as per approved plans.
- Plumbing permit Nov 2024Completed
Repair/replace - curb traap, fresh air inlet, main drain, 1" water distribution
- Electrical permit Aug 2024Completed
Install 400 amp electrical service, meter socket and circuit breaker panel with proper grounding. rewire house throughout and install lighting, switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans
- General permit Aug 2024Expired
For the removal of one (1) 550 gallon underground storage tank with monitoring and piping. all work to be done in accordance with manufacturer specifications, pennsylvania d.e.p. regulations, all applicable codes, nfpa 30 and nfpa 31. **subject to the following condition of the philadelphia historical commission: the tank is to cut into piece small enough to allow for its removal without modifications to the exterior facades.
- Residential building permit Jun 2024Issued
**no excavation is approved nor proposed on this permit. replace basement slab with no excavation with like in kind 3 1/2" thick slab. existing habitable basement height is 7ft minimum***renovation of existing single-family home per plan; new interior partitions per plan; structural improvements per plan including ledgering and sistering of floor joists; reframing of roof; install elevator; remove and replace basement floor; no underpinning. new plumbing, electrical, and hvac on separate permit see philadelphia historical approval: accepted per original submission and per revised plans dated 4-25-2024. if window replacement is necessary submit model, cut sheets, elevation drawing & section drawing to phila. historical commission staff. submit design of rear railing prior to installation. **amended 7/9/25-or the additional depth of the basement, a riser was inserted at the threshold of door 001, and two steps were added at the rear bay bump out. the depth of this bump out was not increased by underpinning and remains “as is" door 017 was added providing access to the rear light well b-01 entertainment room different cabinetry layout from previously removal of the mechanical closet, this function is happening in b-02 mechanical room b-05 laundry has been repurposed and slightly resized as a storage room. b-07 laundry has been reduced in size and relocated. original b-07 storage re-numbered. b-08 bathroom has been moved towards the front of the home, and the laundry room moves in it’s former location (approximately) to allow for natural light into the bathroom. b-09 workout room has reduced in size. the entry has been updated to show two additional storage closets for this space. **and green roof**no other exterior or changes approved on this***see sp-2025-000168 for underpinning work and slab**no exterior changes approved on this
- Zoning permit May 2024Issued
For the erection of a roof deck addition with access structure for use as a single-family dwelling; size and location as per application/plan.
- Zoning permit Apr 2024Issued
Residential - household living - single-family
- Residential building permit Feb 2024Completed
Non-structural interior demolitions of an existing single-family structure, details as shown on plan. separate permits required for renovation and trade jobs.
- General permit Sep 2023Completed
For the erection of a fence to serve as a garage door.
Philadelphia Department of Licenses and Inspections
Safety and environment
FEMA natural hazard risk
Relatively High
Highest for this area: inland flooding, heat wave. These drive insurance cost here.
FEMA National Risk Index, census tract
Leaking fuel tanks
3 within 1,650 ft
Nearest: 2400 South St, 2400 South St (950 ft), no further action. Every release here is closed by the state regulator.
EPA UST Finder, leaking underground storage tank releases
Radon potential
Moderate
Average indoor levels of 2 to 4 pCi/L. EPA still suggests testing ground-floor and basement units.
EPA and USGS Geologic Radon Potential Map
Nearest public schools
1,700 ft
Greenfield Albert M Sch (1,700 ft), Freire CS (2,200 ft), Marian Anderson Neighborhood Academy (2,500 ft). Confirm the assigned school with the district.
U.S. Department of Education, NCES
Major airport
6.2 mi
Philadelphia International (PHL). Aircraft may be audible under approach paths.
FAA large-hub airports
Conforming loan limit 2026
$832,750
Philadelphia County. Mortgages up to this amount qualify for Fannie Mae and Freddie Mac pricing. Above it, the loan is a jumbo with stricter terms.
FHFA Conforming Loan Limit Values, one-unit
Have you lived here? Share your experience.
Leave a reviewThe Address Story
Every address has a context. Read its story.
How much it costs to live here
Price, rent, mortgage, and the city's economic context, all in one place.
The money at this address
Renting, buying, and investing, on the same numbers. Enter the listing price to see all calculations.
Enter a rent and the yield calculation fills in on its own.
Loan calculator for this address
Enter the listing price. The calculation uses only your numbers.
Rough estimate, with a fixed rate. The bank's offer may include fees and insurance.
More on Delancey Place
All addressesViewing recommendations
What's worth checking in person before deciding.
- Test water pressure and temperature at the tap, in the bathroom and kitchen, for at least a minute.
- Look at the stairwell (cleanliness, smell) and the association's notice board: unpaid dues, conflicts, recent decisions.
- Ask for the latest maintenance bill from a winter month, not a summer one: that's where the real cost of living there shows up.
- Knock on a neighboring door and ask two things: what bothers them most often, and what work is planned for the building.
- Ask specifically where you'd park: is there paid city parking, who currently holds it, what the permit costs, and how long the waitlist is.
- Schedule a viewing on a weekday too, between 6:00 and 7:30 PM, the window when the building is busiest: neighbors, parking, elevator.
Neighborhood recommendations are derived from public OpenStreetMap data and may be incomplete. Checking in person is still what matters most.
The year built, height regime, structure, and elevator for this address are being indexed right now, city by city. Save the page and check back: it fills in over time. If you live here, you can fill it in yourself in a minute by leaving a review.